Restek Corporation
Restek Corporation
  • Видео 103
  • Просмотров 1 033 061
Your Partner in PFAS Analysis
Rely on Restek’s experience as a global leader in PFAS analysis. From app notes and webinars to advanced sample prep and analytical techniques, leverage our expertise in PFAS for your analysis.
Filmed in association with LabCompare.
-----------------------------------------------------------------
Additional Resources
Explore Our Vast Library of PFAS Resources | www.restek.com/PFAS
-----------------------------------------------------------------
Restek Recommended Tools & Parts
LC PFAS Products | www.restek.com/c/lc-pfas
Reference Standards PFAS Products | www.restek.com/c/rs-pfas
Sample Preparation PFAS Products | www.restek.com/c/sp-pfas
Air & Gas Sampling PFAS Products | www.restek.com/c/AG...
Просмотров: 115

Видео

Restek at analytica 2024
Просмотров 2703 месяца назад
We just returned from another fantastic analytica. Waffles, a quiz, and plenty of chromatography. If you were able to join us, thank you! And if not, you can see a little of what you missed and make your plans for the next analytica! Connect with Us RUclips: ruclips.net/user/RestekCorp LinkedIn: www.linkedin.com/company/restek-corporation/ Facebook: RestekCorporation
Syringe Care and Maintenance for Chromatographers
Просмотров 2,9 тыс.Год назад
Many chromatographers rely on syringes every day to do their work. They need to be accurate and consistent, but also reliable and dependable whether you use them manually or in an autosampler. In this Restek Tip, we cover syringe care and maintenance. What steps can you take to guarantee a long life for your syringe? And how should you properly maintain it to keep it in tip-top condition? Addit...
LC UV Detector Issues
Просмотров 2 тыс.Год назад
UV detectors are the most common type used in liquid chromatography. Many of us rely on them every day, but if you start to notice errors in your chromatogram, there could be a problem with your detector. In this Restek Tip, we look at some of the issues you might encounter with a UV detector. What should you look out for and what troubleshooting steps can you take? Additional Resources Effecti...
Syringe Basics for Chromatography
Просмотров 3 тыс.Год назад
From sample preparation to sample injection, syringes cover a range of uses in every chromatography lab. But with so many types and options available, how do you know which one to choose? In this Restek Tip, we guide you through a straightforward decision-making process to help you choose a new syringe. Contents 0:00 Choosing A New Syringe 0:19 Consider Your Application 0:44 Gas Tight or Liquid...
LC Leak Checking
Просмотров 2,2 тыс.Год назад
Leaks are one of the most common problems users encounter when performing liquid chromatography. Even the smallest leak in your LC system can cause a loss of sample, a drop in efficiency, and break your entire analysis workflow. In this Restek Tip, we investigate the signs of a possible leak and outline the troubleshooting steps you should take if a leak is discovered. Additional Resources Effe...
Pro EZLC Software Simplifies LC Method Development
Просмотров 1,5 тыс.Год назад
LC method development typically involves a lot of trial and error. It occupies precious lab resources and can take a considerable amount of time. Our Pro EZLC chromatogram modeler dramatically speeds up LC method development. Add analytes, test column chemistries, and optimize run conditions virtually and instantly-without needing to make a single injection. And it’s completely free to use. Add...
When and Why to Use an Electronic Flowmeter
Просмотров 2,8 тыс.2 года назад
Flowmeters are often seen as essential tools for gas chromatography labs. But, since modern GC instruments feature advanced pressure controls, valves, and built-in flow measurement software, is it necessary to have a handheld electronic flowmeter device? In this Restek Tip, we share some situations where an electronic flowmeter can be used and look at the benefits of using one instead of your i...
What Do You Do with a New LC Column?
Просмотров 12 тыс.2 года назад
Before you can use a new LC column to perform analyses, there are a few important steps you need to do to prepare it for its new life in your lab. In this Restek Tip, we show you how to set up your new LC column. We cover certificate of analyses (CofAs), discuss the different column end-fittings you can use, share how to condition your column for your mobile phase, and finally, we’ll look at ho...
Optimizing Split Injections
Просмотров 6 тыс.2 года назад
When performing a split injection, there are several considerations to keep in mind to improve the quality of your chromatography. But what should you change and why? In this Restek Tip, we’re going to show you how to optimize your split injections. We’ll start with liner selection, before discussing the importance of split ratios. Next, we’ll focus on optimizing the inlet temperature, and fina...
3 Ways to Reduce Your Helium Usage
Просмотров 3,4 тыс.2 года назад
Helium scarcity continues to be a pain point for gas chromatography. Prices are trending upward, supplies can be hard to source, and it’s a problem that isn’t going to go away. In this Restek Tip, we share three different ways to reduce your gas usage to get the most out of your helium cylinders. Chapters 0:00 The Trouble with Helium 0:23 Leak Checking Your GC 1:05 GC Gas Saver Mode 2:22 Shutti...
What You Need to Know About Gas Regulators
Просмотров 11 тыс.2 года назад
Gas regulators are fascinating devices and necessary tools in many chromatography applications. But with many options available and multiple variables to consider, choosing the right one can be a difficult task. In this Restek Tip, we share what you need to know about gas regulators. What are the differences between them? And what should you consider when selecting one? Additional Resources How...
Installing the SPME Arrow Conversion Kit
Просмотров 2,3 тыс.2 года назад
The SPME Arrow is a robust and versatile sample preparation device. To take full advantage of its many benefits, you first need to configure your GC. In this Restek Tip, we outline the parts you need, show you how to correctly install them, and answer some common questions. Solid phase microextraction, or SPME, is a fast and versatile sample preparation technique that reduces sample handling an...
What is SPME?
Просмотров 17 тыс.2 года назад
Solid phase microextraction, or SPME, is a fast and versatile sample preparation technique that reduces sample handling and solvent consumption. It can be used for headspace and immersion sampling while producing very clean extracts. In this Restek Tip, we explore the basics of SPME. What is it? How does it work? And what are its advantages? Additional Resources High-Performing Restek PAL SPME ...
Optimizing Splitless Injections
Просмотров 21 тыс.2 года назад
Splitless injections excel at trace analyses, but to get to get the most out of a splitless analysis, it’s important to optimize your system. But what should you optimize and what are the benefits? In this Restek Tip, we’re going to show you how to optimize your splitless injections. We’ll start with liner selection, before discussing the importance of the splitless hold time. Next, we’ll focus...
Why Are There so Many C18 LC Columns?
Просмотров 12 тыс.3 года назад
Why Are There so Many C18 LC Columns?
Rapid Screening & Confirmation of Analytes in Biofluids Using a Single Sample and Sampling Device
Просмотров 1 тыс.4 года назад
Rapid Screening & Confirmation of Analytes in Biofluids Using a Single Sample and Sampling Device
LC-MS/MS Analysis of Glyphosate & Other Polar Contaminants in Food with an Ion Exchange/HILIC Column
Просмотров 2 тыс.4 года назад
LC-MS/MS Analysis of Glyphosate & Other Polar Contaminants in Food with an Ion Exchange/HILIC Column
Automated In-Line Pigment Removal for Multi-Residue Pesticide Analysis in Spinach by LC-MS/MS
Просмотров 1,1 тыс.4 года назад
Automated In-Line Pigment Removal for Multi-Residue Pesticide Analysis in Spinach by LC-MS/MS
Analysis of the California List of Pesticides and Mycotoxins in Edibles
Просмотров 1,7 тыс.4 года назад
Analysis of the California List of Pesticides and Mycotoxins in Edibles
Coated Blade Spray-Tandem MS for Rapid Screening & Quantitation of Drugs in Oral Fluids
Просмотров 1,1 тыс.4 года назад
Coated Blade Spray-Tandem MS for Rapid Screening & Quantitation of Drugs in Oral Fluids
Split vs. Splitless Injection
Просмотров 123 тыс.4 года назад
Split vs. Splitless Injection
How to Store Reference Standards
Просмотров 4,8 тыс.4 года назад
How to Store Reference Standards
Sonicating Your Reference Standard
Просмотров 4,8 тыс.4 года назад
Sonicating Your Reference Standard
Preparing a New Reference Standard for Use
Просмотров 8 тыс.4 года назад
Preparing a New Reference Standard for Use
10 Places to Check for GC Gas Leaks
Просмотров 10 тыс.4 года назад
10 Places to Check for GC Gas Leaks
Correctly Using a Press-Tight Connector
Просмотров 4,4 тыс.4 года назад
Correctly Using a Press-Tight Connector
GC Particle Traps
Просмотров 3,8 тыс.4 года назад
GC Particle Traps
What is QuEChERS?
Просмотров 22 тыс.4 года назад
What is QuEChERS?
Connecting GC Columns Using a SilTite µ-Union
Просмотров 6 тыс.4 года назад
Connecting GC Columns Using a SilTite µ-Union

Комментарии

  • @Mandenga100
    @Mandenga100 5 месяцев назад

    You guys are explaining this so good. I use your video's to show my students about how to troubleshoot!

    • @RestekCorp
      @RestekCorp 5 месяцев назад

      Wow, thank you!

  • @okyoros
    @okyoros 6 месяцев назад

    Thank you for such wonderful explanation.

  • @kobedierckx2918
    @kobedierckx2918 6 месяцев назад

    Nice video! this is in my school materials, i could see what bleeding is on a graph but couldn't put it in the right words. Now i know that it is additional unwanted signals in the graph caused by the degradation of the stationary phase caused by a reactive chemical like a strong acid or base or by oxygen contamination so it is very important to filter for oxygen in the carrier gas.

  • @oliveoil6195
    @oliveoil6195 6 месяцев назад

    Hi, thank you for the video! Can you tell me a little bit about the difference between a fixed flow regulator and a variable flow regulator?

  • @al_musstafa5843
    @al_musstafa5843 6 месяцев назад

    Hello, how much is the value of the lamp based on its voltage?

  • @zahradashtbozorgi7469
    @zahradashtbozorgi7469 6 месяцев назад

    Thanks that was very helpful. Please make a video about maintaining the ECD detector. thanks

  • @jey8436
    @jey8436 7 месяцев назад

    After how many injections, (on average), should the filter be replaced? And what about cleaning the split vent lines?

    • @RestekCorp
      @RestekCorp 6 месяцев назад

      This can vary greatly. As a default, we'd always recommend checking with your instrument manufacturer's guidelines. These are generally around every six months. How much you are injecting, how much is your split, how dirty are your samples can all impact this. Cleaning split vent lines is generally reserved for a situation where you feel it is needed, such as seeing some ghost peaks or other evidence of contamination. In an extreme case, when you notice incorrect flow rates and may suspect some clogging.

  • @ronesoares6164
    @ronesoares6164 7 месяцев назад

    Obrigado

  • @ronesoares6164
    @ronesoares6164 7 месяцев назад

    Sou de São Paulo Brasil e trabalho com um cromatógrafo com duas colunas e quando injeto a mesma amostra nos dois, tem muita diferença no resultado, e sinal do fid do front e 6,2 e do back está em 7,8. vou fazer um vídeo e mostrar aqui nos comentários ok.

  • @ronesoares6164
    @ronesoares6164 7 месяцев назад

    Obrigado pela informação

  • @ronesoares6164
    @ronesoares6164 7 месяцев назад

    Muito obrigado amigo, moro em São Paulo Brasil, e trabalho com um cromatógrafo com duas colunas e uma está com o sinal (fid) muito alto, o front está com 6,2 e o back com 7,8, quando injeto a mesmo amostra nos dois, dá uma diferença, e também no final da corrida e sinal aumenta muito. Vou fazer um vídeo mostrando o ocorrido.

  • @2339091q
    @2339091q 7 месяцев назад

    Thank you so much!

  • @lorenzojercan1793
    @lorenzojercan1793 7 месяцев назад

    The blank must be the same as the mobile phase?

  • @sooncheongkwan9007
    @sooncheongkwan9007 9 месяцев назад

    Hi, can you show us how to replace the frit Agilent 1290 system?

  • @radi675
    @radi675 9 месяцев назад

    do you offer the split vent trap for shimadzu GC2030? The new design for 2030 is offered at hilariously outrageous $200/unit.

    • @RestekCorp
      @RestekCorp 9 месяцев назад

      Hello, I'm sorry, this is not a product that we offer. Thank you for asking!

  • @meme2403
    @meme2403 10 месяцев назад

    You talk about the initial oven temperature, does this mean that the separation was carried out in temperature programming mode? Tank you.

    • @RestekCorp
      @RestekCorp 10 месяцев назад

      Generally yes, but it doesn't need to be.

  • @amirrulhakim01
    @amirrulhakim01 10 месяцев назад

    Can you help me, the back detector shows temp not installed. And my infront gas (N2) flow rate i set is 45, but the screen show range 51 - 60. Can you help?

  • @technicalvinayak6959
    @technicalvinayak6959 10 месяцев назад

    *Make video on TCD*

  • @kalaimathim220
    @kalaimathim220 10 месяцев назад

    I have faced an ignition cut-off when the sample was injected. Upto injection of sample flame is on and shows a good signal. but when injected immediately, the ignition will cut. what is the reason? can you please tell me?

    • @RestekCorp
      @RestekCorp 10 месяцев назад

      What are you injecting and how much? You may wish to troubleshoot by trying to inject less or a different solvent. You can also do an no injection instrument blank to see if it is a timing/flow issue rather than the injection itself. You can find instructions on how to do that here ruclips.net/video/tpebPhvQERY/видео.htmlsi=DNIgtobWEzHsxpe3

  • @chakhonglam2444
    @chakhonglam2444 11 месяцев назад

    I have an Agilent ZORBAX NH2 and Carbohydrate column which is used for HILIC separation for sugar. Since those 2 columns have not been used for a period of time. Which solvents are suitable to use for cleaning and regeneration?

    • @RestekCorp
      @RestekCorp 10 месяцев назад

      For any specific column, we would always recommend referencing the original manufacturer's instructions. Here is some information that may be helpful www.agilent.com/cs/library/datasheets/public/820629-008D.pdf For general information on LC column regeneration, we have a nice blog post www.restek.com/chromablography/resurrecting-an-old-reverse-phase-lc-column--should-i-could-i-how-would-i

  • @mountfuji3330
    @mountfuji3330 Год назад

    Can you explain what's the purpose of the serrated edge, please? (Assuming there is a purpose).

    • @RestekCorp
      @RestekCorp 11 месяцев назад

      In the past, the serrated edge was recommended for use for cutting some smaller ID metal columns. Generally, even those are now recommended to be cut with the smooth edge.

    • @mountfuji3330
      @mountfuji3330 11 месяцев назад

      @@RestekCorp Thank you for the information.

  • @SasiKumar-lg1wc
    @SasiKumar-lg1wc Год назад

    What is the makeup gas?

  • @SasiKumar-lg1wc
    @SasiKumar-lg1wc Год назад

    Whis is mechanisms of FID detector

    • @Dr.AmzadHossain
      @Dr.AmzadHossain 8 месяцев назад

      Could you please make a complete video for working Software and analysis details step by stem

  • @SasiKumar-lg1wc
    @SasiKumar-lg1wc Год назад

    How to remove the flowcell contamination?

  • @SasiKumar-lg1wc
    @SasiKumar-lg1wc Год назад

    What is difference between RI,PDA,Uv dectors

  • @SasiKumar-lg1wc
    @SasiKumar-lg1wc Год назад

    How to reduce the column back pressure?

  • @SasiKumar-lg1wc
    @SasiKumar-lg1wc Год назад

    Which solvent suitable for c18 columns?

  • @SasiKumar-lg1wc
    @SasiKumar-lg1wc Год назад

    How to remove the column blockage?

  • @HenoMarkarian
    @HenoMarkarian Год назад

    Can one extrapolate two neighbor peaks with resolution below 1.0? Is it correct to integrate the area of extrapolated peaks that are artificially deconvoluted?

  • @thilpanneerpanneer2327
    @thilpanneerpanneer2327 Год назад

    Pl.tell about collector assembly sir

  • @thilpanneerpanneer2327
    @thilpanneerpanneer2327 Год назад

    What is the principal behind FID Jet

  • @thilpanneerpanneer2327
    @thilpanneerpanneer2327 Год назад

    How to clean the FID jet and how to know jet is damaged,?

  • @thilpanneerpanneer2327
    @thilpanneerpanneer2327 Год назад

    Good Explanation sir.

  • @thilpanneerpanneer2327
    @thilpanneerpanneer2327 Год назад

    What is the minimum syringe injection volume during method optimisation

  • @thilpanneerpanneer2327
    @thilpanneerpanneer2327 Год назад

    We are use mostly Exmair syringe.After 100 injection , syringe response wasn't good.What is the best syringe and rugged

  • @thilpanneerpanneer2327
    @thilpanneerpanneer2327 Год назад

    What basis syringe(10 micro or 5 micro litre) to be chosen based on injection volume 1 micro litre

  • @thilpanneerpanneer2327
    @thilpanneerpanneer2327 Год назад

    Why syringe is struck after 8 injection of DMSO mostly

  • @ArchanaBhamre-gp7ii
    @ArchanaBhamre-gp7ii Год назад

    Thank you for ur guidance ...it's really helpful...thank you...sir

  • @Icyblaze...
    @Icyblaze... Год назад

    We got solvent peak but no sample peak. Any advice for this? Thanks! Appreciate your assistance.

  • @yohandudognon4108
    @yohandudognon4108 Год назад

    What about chemicals with labile hydrogen such as carboxylic acid due to the column ? Is there a way to avoid peak tailing ?

    • @RestekCorp
      @RestekCorp Год назад

      Compounds like carboxylic acids, can be very difficult to get good peak shapes. Depending on the column phase, there may be columns specifically designed to work with acids that can help. Stabilwax-DA columns are an example. Derivitization is also used for some compounds to improve peak shapes - fatty acids are often methylated before being analyzed for this reason. Some analysts also do priming injections - injecting high concentration standards to help occupy active sites before doing their analytical injections. There are many options, but they can all have their pros and cons.

  • @quimicamentefalando
    @quimicamentefalando Год назад

    Congratulations for the video, but I don't understand how a pulsed split injection can have the liner with increased pressure if the injector outlet opens?

    • @RestekCorp
      @RestekCorp Год назад

      The pressure controls of the GC system are designed to handle these pressure changes. So while there is still flow going through the column (and out the split vent, septum purge, etc.) pulsed injection allows users to temporarily elevate the pressure in the injection port.

    • @quimicamentefalando
      @quimicamentefalando Год назад

      @@RestekCorp Great! Thank you for this.

    • @RestekCorp
      @RestekCorp Год назад

      You're welcome!

  • @salve1185
    @salve1185 Год назад

    sir why do you need to cut the column? what is the purpose of cutting a column?

  • @franleblanc
    @franleblanc Год назад

    Came to watch how to properly re-install the collector assembly. I also am having a hard time.

  • @alahamomand33
    @alahamomand33 Год назад

    I am studying for my Chromatography course and this video was literally so well made. Thank you!

  • @dhirenkc6748
    @dhirenkc6748 Год назад

    Hi sir, In case of benzene in carbomer as per USP method ... the benzene standard getting deterioration after 1 or 2 injections through splitless mode where i have been connected with split line in the GC...is this problem are having connection with split liner...

  • @ameno0224
    @ameno0224 Год назад

    Could anyone recommend me packed column can separate oxygen, nitrogen and CO to tcd?

  • @destinyhagendorfer-is8no
    @destinyhagendorfer-is8no Год назад

    Where can I get the cap for the septum purge?

    • @RestekCorp
      @RestekCorp Год назад

      That will depend on your instrument. Many can use standard compression fitting caps, but you should check your instrument manual or instrument manufacturer to be sure.

  • @user-gf6mt3bd4k
    @user-gf6mt3bd4k Год назад

    I'm careful if I can ask here, but is it possible to analyze isophthalic acid by GC-MS? I have been having a tailing problem for a month. I will buy all the products you recommend. Somebody help me T^T

    • @maracchi2046
      @maracchi2046 Год назад

      Tailing happens when the analyte of interest retains in the column. How the oven is programmed, gas flow rate, or the column used could impact your acid. You might need to look into different columns since you are dealing with aromatic acids, like Chromaton N-AW-HMDS with 5% Apiezon L column.

  • @user-dk7nb3dm4y
    @user-dk7nb3dm4y Год назад

    Each video is too short,Can some long videos provided to explain the details?